20-fold metered PDU
Expert PDU Energy 8311 for more security and energy efficiency in IT and AV installations (not switched)
- Demonstrably fewer and shorter outages of your critical IT and AV infrastructure
- Detect AV and IT problems at an early stage: Proactive power and environment monitoring
- Increased energy efficiency (Green IT and AV): Reduction of electricity costs and CO2 emissions
- Integrate anywhere: Quickly and easily integrate anywhere with API interface: REST API, HTTPS, SNMP, Telnet and MQTT
Key Features
- Precise current metering of up to 9 units and residual current
- 1 connector for plug-and-play sensors
- Fast and easy installation
- NTP function can be activated
- Supports Radius- und Modbus TCP protocol
---------------------------------------------------------------------------------------------------------------
Expert PDU Energy 8311 – เพื่อความปลอดภัยและประสิทธิภาพพลังงานที่ดียิ่งขึ้นในงานติดตั้ง IT และ AV (ไม่ใช่รุ่นสวิตช์ได้)
-
ลดจำนวนและระยะเวลาของเหตุขัดข้องในโครงสร้างพื้นฐาน IT และ AV ที่สำคัญได้อย่างชัดเจน
-
ตรวจจับปัญหา AV และ IT ได้ตั้งแต่ระยะเริ่มต้น: การตรวจสอบพลังงานและสภาพแวดล้อมเชิงรุก
-
เพิ่มประสิทธิภาพการใช้พลังงาน (Green IT และ AV): ลดค่าไฟฟ้าและการปล่อยก๊าซคาร์บอนไดออกไซด์
-
ผสานรวมได้ทุกที่: รองรับการเชื่อมต่ออย่างรวดเร็วและง่ายดายผ่าน API interface: REST API, HTTPS, SNMP, Telnet และ MQTT
คุณสมบัติหลัก
-
การวัดค่ากระแสไฟฟ้าที่แม่นยำสูงได้ถึง 9 หน่วย พร้อมการตรวจจับกระแสรั่ว (Residual Current)
-
มีช่องเชื่อมต่อสำหรับเซนเซอร์แบบ Plug-and-Play 1 ช่อง
-
ติดตั้งได้รวดเร็วและง่ายดาย
-
รองรับการตั้งค่า NTP (Network Time Protocol)
-
รองรับโปรโตคอล Radius และ Modbus TCP


Technical Details
- Measurement of key electrical parameters: current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- LxWxH: 87 x 4.4 x 4.4 cm (without mounting brackets)
- Weight: approx. 2.5 kg
- Length of mains cable: 3 m
- Operating temperature: 0-50 °C
- Storage temperature: -20 – 70 °C
- Relative humidity: 0 – 95 % (non condensing)
Electrical Connections
- 1 power supply safety socket type F (max. 16 A, 230 V)
- 4 power ports IEC C19 (max. 16 A) and 16 outlet ports IEC C13 (max. 10 A) for 8311-15, 8311-16
- 1 Ethernet connector RJ45 (10/100 Mbit/s)
- 1 sensor connector (RJ45) for plug-and-play sensors
Technical Details
- Measurement of key electrical parameters: current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- LxWxH: 87 x 4.4 x 4.4 cm (without mounting brackets)
- Weight: approx. 2.5 kg
- Length of mains cable: 3 m
- Operating temperature: 0-50 °C
- Storage temperature: -20 – 70 °C
- Relative humidity: 0 – 95 % (non condensing)
Electrical Connections
- 1 power supply safety socket type F (max. 16 A, 230 V)
- 4 power ports IEC C19 (max. 16 A) and 16 outlet ports IEC C13 (max. 10 A) for 8311-15, 8311-16
- 1 Ethernet connector RJ45 (10/100 Mbit/s)
- 1 sensor connector (RJ45) for plug-and-play sensors
Metering function
- Power consumption metering (kwH) with 2 energy counters: one counter counts consistently, the other counter is resettable
- Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
- Metering of differential current type A (mA)
- 1 connector for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure
Security
- Generation of status messages and alarms (e-mail, syslog, SNMP traps MQTT, SSH, Telnet)
- Encrypted e-mails (SSL, STARTTLS)
- Access protection by IP access control
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- Password protected access
- Beeper for audible alarm when sensor limits are exceeded/deceeded
Operation
- Easy-to-read LED display for displaying total current, IP address and sensor values
- Firmware update via Ethernet during operation (no restart required)
- Simple and flexible configuration via web browser, Windows or Linux program
- Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
- Rapid commissioning thanks to free and reliable drivers from our technology partners