GWS-DP24-24 is one economical slim 24W industrial DIN Rail power supply series, adapting to be installed on TS-35/7.5 or TS-35/15 mounting rails. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.
GWS-DP24-24 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 85%, the entire series can operate at the ambient temperature between -40? to 70? under air convection. It is equipped with constant current mode for over load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus make GWS-DP24-24 a very competitive power supply solution for industrial applications.
Feature
• Power Input: AC 90~264V
• Support production for short circuit/over current/over voltage
• Wide operation temperature range: -40?~70?
• 100% full load aging test
• High efficiency, long life time and high reliability
• Meet EMC Standard
Product Name
24W/24V Industrial DIN Rail Power Supply
Model
GWS-DP24-24
Group of Output
1
DC Voltage
24V DC
Default Output Voltage
24.00-24.2V ?VIN: 220VAC / LOAD: 0A?
Output Rated Current
1A
Output Current Range
0-1A
Output Rated Power
24W
Total Peak Output Power
Up to 36W(Sustainable time 10S/220VAC)
Peak Output Current
1.5A( Sustainable time 10S/220VAC)
Ripple Noise
Peak - Peak ≤100mV (Test Method: The terminal shall be in parallel with capacitance of 0.1uF and 47uF, testing at 20MHz)
Output Regulation Range
22.5.V~28.0V
Stabilized Voltage Precision
±1% (@ 90-264Vac input, 100% load)
Line Regulation
±0.5% (@ 90-264Vac input, 100% load)
Load Regulation
±1% (@ 90-264Vac input, 100% load)
Temperature Coefficient
±0.03%/?
Output Start Time
< 3S @ 115Vac < 1.6S @ 230Vac (100% load)
Output Hold Time
> 20ms @ 115Vac (100% load)
Voltage Overshoot
≤5%
Input Voltage Range
90~264VAC
Input Rated Voltage Range
100~240VAC
Frequency Range
47Hz~63Hz
Rated Frequency
50/60Hz
Starting Voltage
90V AC
Efficiency
> 85.0% @ 115Vac, > 84.0% @ 230Vac
Input Current
< 0.60A @ 115Vac, < 0.30A @ 230Vac
Inrush Starting Current
< 60A @ 230Vac
Power Factor
>0.6 (at full load)
Over Power Protection
28.8~36W Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-power released.)
Over Voltage Protection
28~30V Swing machine (Short circuit the Pin1-2 of U8, swing machine. Output recovery to normal after removing the short circuit) Note: Do not use external voltage.
Over Current Protection
1.2~1.5A Swing machine (Testing method: Increase the output current until enabling the protection. Protection mode:Swing machine, Self-recovery after over-current released.)
Short Circuit Protection
It achieves the long-term short circuit by connecting a sufficient cross-sectional area copper cable (Length at 15cm±5cm) with power output port. Self-recovery to normal after removing the short circuit.
Operation Temperature and Humidity
-40?70?; 20%?95%RH
Storage Temperature and Humidity
-40?~85?; 10%~95%RH non-condensing
Libration
Frequency range: 10 ~ 500Hz, Acceleration: 2G, Each sweep cycle 10min. Six sweeps along the X, Y, and Z axis
Surge
Acceleration: 20G, Duration time: 11mS, Three shocks along X, Y and Z axis
Altitude
2000m
Security Standard
GB4943/EN60950 ?Reference ?Certification
Dielectric Strength
Input—Output:3KVac/10mA; Input--Case:1.5KVac/10mA; Output---Case:0.5KVDC/10mA Time for each testing is 1min.
Grounding Test
Test Condition: 32A/2min; Ground bond: ?0.1 ohms.
Leakage Current
Input to GND ≤3.5mA; Input to output ≤0.25mA (Input 264Vac, 63Hz)