IP relay control with 8 channels and 8 signal inputs
Expert Net Control 2304-1 for increased operational reliability and energy efficiency in DIN rail installations
- Demonstrably fewer and shorter outages of your critical IT and AV infrastructure
- More control through remote access to switchable relay outputs
- Detect AV and IT problems at an early stage: Proactive environmental monitoring and configurable alarms
- Integrate anywhere: Quickly and easily integrate anywhere with API interface: REST API, https, SNMP, Telnet and MQTT
- Protection against physical hazards with connected smoke detectors, leakage sensors and door contacts
Key Features
- Event and schedule controlled switching
- Signal inputs for polling NO/NC devices (e.g. door contact, smoke detector etc.)
- 1 connector for plug-and-play sensors for real-time monitoring
- Easy and fast mounting on mounting rails with top hat profile
- NTP function can be activated
- More flexibility through Radius, Modbus TCP and MQTT 3.1.1 support
----------------------------------------------------------------------------------------------------------------------
Expert Net Control 2304-1
เพื่อความน่าเชื่อถือในการทำงานและประสิทธิภาพด้านพลังงานที่สูงขึ้นในการติดตั้งบนราง DIN
- ลดจำนวนและระยะเวลาการหยุดทำงานของโครงสร้างพื้นฐาน IT และ AV ที่สำคัญของคุณได้อย่างพิสูจน์แล้ว
- ควบคุมได้มากขึ้นด้วยการเข้าถึงจากระยะไกลเพื่อสวิตช์รีเลย์เอาต์พุต
- ตรวจพบปัญหา AV และ IT ได้ตั้งแต่ระยะเริ่มต้น: ด้วยการมอนิเตอร์สภาพแวดล้อมเชิงรุกและระบบแจ้งเตือนที่สามารถกำหนดค่าได้
- ผสานการทำงานเข้ากับระบบใด ๆ ได้อย่างรวดเร็วและง่ายดายผ่าน API interface: REST API, HTTPS, SNMP, Telnet และ MQTT
- ป้องกันอันตรายทางกายภาพด้วยการเชื่อมต่อเซ็นเซอร์ควัน, เซ็นเซอร์ตรวจจับน้ำรั่ว และคอนแทคประตู
คุณสมบัติหลัก (Key Features)
- ควบคุมการสวิตช์ตามเหตุการณ์และกำหนดตารางเวลาได้
- อินพุตสัญญาณสำหรับตรวจสอบอุปกรณ์ NO/NC (เช่น คอนแทคประตู, เครื่องตรวจจับควัน เป็นต้น)
- คอนเนคเตอร์ 1 ช่องสำหรับ Plug-and-Play Sensors เพื่อการมอนิเตอร์แบบเรียลไทม์
- ติดตั้งง่ายและรวดเร็วบนรางมาตรฐาน Top-hat Profile
- รองรับการใช้งานฟังก์ชัน NTP
- เพิ่มความยืดหยุ่นด้วยการรองรับ Radius, Modbus TCP และ MQTT 3.1.1.



Technical Details
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- Housing form: for mounting rail with top hat profile
- LxHxD: 143 x 65 x 90 mm
- Weight: approx. 400 g
- Operating temperature: 0-45 °C
- Storage temperature: -20 – 70 °C
- Relative humidity: 0 – 95 % (non condensing)
Electrical Connections
- 1 Mains connection with 230 V AC or 30 V DC (terminal clamps)
- 8 switching outputs (terminal clamps)
- 8 passive signal inputs (terminal clamps)
- 1 Ethernet connector RJ45 (10/100 Mbit/s)
- 1 connector (RJ45) for plug-&-play sensors
Switching function
- 8 switchable, potential-free relay outputs with 16 A switching capacity
- Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH, MQTT and serial interface
- Programmable on/off sequences for remote reboots (Remote Reboot)
- Power ports can be switched when preset sensor thresholds are exceeded
- Self-healing function thanks to 8-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
- Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
- Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
Metering function
- 1 connection for combined plug-&-play sensors (temperature, humidity and air pressure) to prevent frequently occurring physical hazards such as overheating and increased humidity or air pressure
Security
- Generation of status messages and alarms (e-mail, syslog, SNMP traps MQTT, SSH, Telnet)
- Encrypted e-mails (SSL, STARTTLS)
- Access protection by IP access control
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- Password protected access
- Beeper for audible alarm when sensor limits are exceeded/deceeded
Operation
- Easy-to-read LED display for displaying total current, IP address and sensor values
- Firmware update via Ethernet during operation (no restart required)
- Simple and flexible configuration via web browser, Windows or Linux program
- Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
- Rapid commissioning thanks to free and reliable drivers from our technology partners